The Pressurized Water Reactor (PWR) plant steam generators, which are normally located inside the primary containment, are located outside, in separate structures. This arrangement provides for the removal or repair of the individual "leaky" steam generators, while the others remain operational. It also significantly reduces the size and thereby the cost of the containment.