2012 to 2012 Weld specialistSpencer Reed Group LLC Long Beach, CA 2012 to 2012 Welder FabricatorSweet Ovations Gardena, CA 2011 to 2011 Maintenance MechanicCalifornia Industrial Systems Arbuckle, CA 2004 to 2011 Welder Fabricators Kitchen Santa Rosa, CA 2002 to 2004 welder FabricatorHruby Mechanical Santa Rosa, CA 2001 to 2002 Welder FabricatorCalifornia Industrial Systems Industrial, California, US 1997 to 1999 Welder FabricatorCorey Delta Benicia, CA 1988 to 1997 Senior Mechanic, pipe fitter
Education:
Redondo Union High School Redondo Beach, CA 1980 Diploma
Name / Title
Company / Classification
Phones & Addresses
Michael Garrison President
Remco Products Corporation Plastics · Mfg Plastic Products · All Other Plastics Prod Mfg
4735 W 106 St, Zionsville, IN 46077 PO Box 698, Zionsville, IN 46077 4734 W 106 St, Zionsville, IN 46077 2550 N 1 St, San Jose, CA 95131 3178769856, 3178769858
- Union City CA, US Hamed Khalilinia - Hayward CA, US Niloofar Torabi - Menlo Park CA, US Michael T. Garrison Stuber - Newman Lake WA, US Sana Tayyab - Lahore, PK Adeel Ahmad Khan - Lahore, PK Haroon Inam - San Jose CA, US
International Classification:
H02J 3/18 H02J 13/00 G01R 31/08 H02H 1/00
Abstract:
Disclosed is a reactance-injecting module and its method of use to balance the currents among the phases of polyphase electric power transmission lines or to manage power flow among alternate paths, where the reactance-injecting module has high-speed, dedicated communication links to enable the immediate removal or reduction of injected reactance from all phases of a phase balancing cluster when a fault is detected on any one of the multiple phases. The reactance-injecting module may communicate information on a detected fault to the other reactance-injecting modules of the phase balancing cluster within 10 microseconds after the fault is detected to allow the phase balancing cluster to eliminate injected reactance from all phases within a time that is short compared to a cycle of the alternating current, such as 1 millisecond after the fault is detected. This provides extremely fast neutralization of injected reactance to minimize interference with fault localization analyses.
- Union City CA, US Hamed Khalilinia - Hayward CA, US Niloofar Torabi - Menlo Park CA, US Michael T. Garrison Stuber - Newman Lake WA, US Sana Tayyab - Lahore, PK Adeel Ahmad Khan - Lahore, PK Haroon Inam - San Jose CA, US
International Classification:
H02J 3/18 H02H 1/00 H02J 13/00 G01R 31/08
Abstract:
Disclosed is a reactance-injecting module used to balance the currents among the phases of polyphase electric power transmission lines or to manage power flow among alternate paths, where the reactance-injecting module has high-speed, dedicated communication links to enable the immediate removal of injected reactance from all phases of a phase balancing cluster when a fault is detected on any one of the multiple phases. The reactance-injecting module may communicate information on a detected fault to the other reactance-injecting modules of the phase balancing cluster within 10 microseconds after the fault is detected to allow the phase balancing cluster to eliminate injected reactance from all phases within 1 millisecond after the fault is detected. This provides extremely fast neutralization of injected reactance to minimize interference with fault localization analyses.